The TOX-ARRAY 2000
Any combination of toxic, combustible and oxygen sensors can be used on the Model 2000. Each sensor is configured with a remote amplifier which generates the standard 4-20 mA signal. The amplifier is housed in an explosion-proof junction box with sensor (UL. CSA). MlL-RAM's TOX-ARRAY sensors are based on time proven electrochemical technology. A unique and innovative approach to sensor design eliminates false alarms and is not affected by changes in temperature and/or humidity and does not react with air: this eliminates zero drift. Interferences typically encountered on other detectors are avoided with the TOX-ARRAY sensors. The result is fast, accurate and reliable response with outstanding sensitivity and selectivity. The TOX-ARRAY sensors are extremely stable with a service life of greater than 3 years and are factory rechargeable. No additional electrolyte is required during the 3 years of life of the sensor charge.
Multiples of the 6-channel controller can be configured in larger enclosures for modular and space efficient expansion of the system.
The Model 2000 is the new generation in microprocessor- based gas detection systems emphasizing simplicity of operation and reliability. The Model 2000 offers tremendous microprocessor-based capability, the simplified design eliminates the complexity encountered in setting up other microprocessor-based systems. It was clearly designed with the end user in mind.
Each channel utilizes a plug-in module featuring a three-digit LED display. High, low and trouble LEDs provide visual indication of alarm status, while an integral buzzer provides audible indication of alarms at the controller.
Programmable relays offer added flexibility in area monitoring and reduced installation cost. Discrete relays for each alarm level are standard in the same 9-1/4"W x 11-1/4"H x 6"D enclosure.
An easy-to-read, backlit LCD prompts you for easy setup of each channel. Push button switches enable the user to address various setup parameters on the LCD and easily program each channel. Alarm set points, relay assignment and function (latching or non-latching) are easily installed for each channel.
The Model 2000 is designed to operate from field selectable 115 / 230 volts AC, 50/60 Hz,12 or 24 volts DC. An optional battery backup with trickle charge circuit is available as well as RS-485.
MIL-RAM Technology, Inc., Gas Detection Systems, 2360 Qume Drive, Suite C, San Jose, CA 95131. Tel: 408-324-0660; Fax: 408-324-1661.